Failure
to carry out regular routine draining, either manually or by float-draining
can have catastrophic results. Compressed air systems can become grossly
contaminated and production schedules seriously disrupted - just because
a simple duty has been neglected.
JORC - TEC 22 eliminates the risk of human error and a possible costly aftermath by providing regular controlled system drai-nage, on time, every time - automatically. The JORC - TEC 22 unit consists of a solid-state timer coupled to a solenoid valve and only requires a simple installation pro-cedure. The unit is suitable for ALL compressed air system components (aftercoolers, dryers, filters, pressure vessels and piping), regardless of their size or capacity - simply adjust the interval and discharge times to suit the particular compressed air system. |
||||||
| The Jorc - TEC 22 is designed to provide a solution for the automatic draining of filter bowls, seperators, dryers, receivers, drip legs and other copressed air system components where condensat and contaminants collect. The draining interval and discharge time can be adjusted according to all requirements. |
|
||||||
|
|||||||
![]() |
|||||||
|
SPECIFICATIONS
|
|||
|
TIMER
|
VALVE
|
||
| INTERVAL
TIME T2 (1 ) DISCHARGE TIME Tl (1 ) MANUAL TEST SWITCH SUPPLY VOLTAGE (2) CURRENT CONSUMPTION OPERATING TEMPERATURE ENVIRONMENTAL PROTECTION CASE MATERIAL CONNECTION INDICATORS |
0.5
- 45 minutes 0.5 -10 seconds 24 to 240 VAC/DC ± 10% 50/60 Hz 4mA MAXIMUM -40°C to +60°C IP 65 NEMA 4 when installed ABS Plastic FR grade DIN 43650A ISO 4400/6952 1 LED (yellow) to indicate On phase 1 LED (yellow) to indicate OFF phase VDE01 10 C |
-TYPE
-IN/OUT PORTS -MAXIMUM WORKING PRESSURE -MIN./MAXIMUM TEMPERATURE -MEDIA TEMPERATURE -VALVE BODY -INSULATION -ENVIRONMENTAL PROTECTION -24V - 240V AVAILABLE -VOLTAGE TOLERANCE - MOUNTING IN ANY POSITION |
2/2-Way
direct acting valve 3/8" BSP-female 16 Bar g. 2° C/55°C ambient. Max. 90° C. Forged Brass, orifice 4.5 mm. Thermal group H (200°C) IP 65 See coil for correct voltage ± 10% |
![]() |
![]() |
Note: |
![]() |
| Information provided herewith is believed to be accurate and reliable. However, no responsibility is assumed for its use of for any infringement of patents or rights of others which may result from its use. In addition, JORC reserves the right to revise information without notice and without incurring any obligation. |